Analgesia Meter Hot Plate Advanced
 |
- Rapid screening of analgesic drugs when a heat stimulus is applied to the plantar surface of
the animal paw
- Digital setting of the hotplate temperature from 35°C to 60° C in 0.1° steps
- Time recording with an accuracy of ±0.1 s, maximal test duration is limited to 3 minutes
- Digital display for recording the measured values and test control
- Optional Software Package for data organization and transfer to Excel
|

Analgesia Meter Tail Flick Advanced
 |
- Evaluation of analgesic activity by measuring drug-induced changes in the sensitivity of small
laboratory animals to a heat stress applied to their tails
- Measuring unit for directing a focused light beam with a high proportion of infrared radiation,
i.e. heat, onto the animal's tail
- Digital control unit with display to show continuously the elapsed time and the set intensity
- Limitation of the test time to 60 seconds; the lamp is then switched off automatically and a
warning message is displayed
- Optional Software Package for data organization and transfer to Excel
|

Analgesia Meter Randall Selitto Advanced
 |
- Accurate screening of analgesic drugs on the normal and inflamed paw of small laboratory
animals, according to the Randall-Selitto method
- Measuring unit with force sensor and status LED to indicate the sensor operating state
- Sensor speed matched to the conditions at the pressure tip - quicker sensor speed at first and
then, when touching the paw, a slower speed to approach the pain threshold in small step
- Setting of a minimum and maximum force value, if values above the maximum are reached then the
sensor moves upward automatically
- Optional Software Package for data organization and transfer to Excel
|

Power Meter - Incapacitance Tester
 |
- Incapacitance tester for determination of the weight distribution on the two hind paws of a
small animal to screen analgesic or anti-inflammatory drug effects
- Measurement of the applied force via a built-in force transducer connected to two small contact
platforms
- Available for animals of rat or mouse size - different types of restraining cage are available
- Production of a force graph after the test with calculation of the maximum force for each
channel as well as the average value over the length of the trial
- Powermeter software for windows for controlling the trial and for recording and storing the
measuring data (force)
|


Copyright © 1995 - 2009 TSE Systems International Group - All rights reserved.
|